summaryrefslogtreecommitdiffstats
path: root/PendingReleaseNotes
blob: db15241d205c77b10b623507aa5c6e66fbc393b7 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
>=15.0.0
--------

* The RGW "num_rados_handles" has been removed.
  * If you were using a value of "num_rados_handles" greater than 1
    multiply your current "objecter_inflight_ops" and 
    "objecter_inflight_op_bytes" paramaeters by the old
    "num_rados_handles" to get the same throttle behavior.

* Ceph now packages python bindings for python3.6 instead of
  python3.4, because python3 in EL7/EL8 is now using python3.6
  as the native python3. see the `announcement <https://lists.fedoraproject.org/archives/list/epel-announce@lists.fedoraproject.org/message/EGUMKAIMPK2UD5VSHXM53BH2MBDGDWMO/>_`
  for more details on the background of this change.

* librbd now uses a write-around cache policy be default,
  replacing the previous write-back cache policy default.
  This cache policy allows librbd to immediately complete
  write IOs while they are still in-flight to the OSDs.
  Subsequent flush requests will ensure all in-flight
  write IOs are completed prior to completing. The
  librbd cache policy can be controlled via a new
  "rbd_cache_policy" configuration option.

* librbd now includes a simple IO scheduler which attempts to
  batch together multiple IOs against the same backing RBD
  data block object. The librbd IO scheduler policy can be
  controlled via a new "rbd_io_scheduler" configuration
  option.

* RGW: radosgw-admin introduces two subcommands that allow the
  managing of expire-stale objects that might be left behind after a
  bucket reshard in earlier versions of RGW. One subcommand lists such
  objects and the other deletes them. Read the troubleshooting section
  of the dynamic resharding docs for details.

* RGW: Bucket naming restrictions have changed and likely to cause
  InvalidBucketName errors. We recommend to set ``rgw_relaxed_s3_bucket_names``
  option to true as a workaround.

* In the Zabbix Mgr Module there was a typo in the key being send
  to Zabbix for PGs in backfill_wait state. The key that was sent
  was 'wait_backfill' and the correct name is 'backfill_wait'.
  Update your Zabbix template accordingly so that it accepts the
  new key being send to Zabbix.

* zabbix plugin for ceph manager now includes osd and pool
  discovery. Update of zabbix_template.xml is needed
  to receive per-pool (read/write throughput, diskspace usage)
  and per-osd (latency, status, pgs) statistics

* The format of all date + time stamps has been modified to fully
  conform to ISO 8601.  The old format (``YYYY-MM-DD
  HH:MM:SS.ssssss``) excluded the ``T`` separator between the date and
  time and was rendered using the local time zone without any explicit
  indication.  The new format includes the separator as well as a
  ``+nnnn`` or ``-nnnn`` suffix to indicate the time zone, or a ``Z``
  suffix if the time is UTC.  For example,
  ``2019-04-26T18:40:06.225953+0100``.

  Any code or scripts that was previously parsing date and/or time
  values from the JSON or XML structure CLI output should be checked
  to ensure it can handle ISO 8601 conformant values.  Any code
  parsing date or time values from the unstructured human-readable
  output should be modified to parse the structured output instead, as
  the human-readable output may change without notice.

* The ``bluestore_no_per_pool_stats_tolerance`` config option has been
  replaced with ``bluestore_fsck_error_on_no_per_pool_stats``
  (default: false).  The overall default behavior has not changed:
  fsck will warn but not fail on legacy stores, and repair will
  convert to per-pool stats.

* The disaster-recovery related 'ceph mon sync force' command has been
  replaced with 'ceph daemon <...> sync_force'.

* The ``osd_recovery_max_active`` option now has
  ``osd_recovery_max_active_hdd`` and ``osd_recovery_max_active_ssd``
  variants, each with different default values for HDD and SSD-backed
  OSDs, respectively.  By default ``osd_recovery_max_active`` now
  defaults to zero, which means that the OSD will conditionally use
  the HDD or SSD option values.  Administrators who have customized
  this value may want to consider whether they have set this to a
  value similar to the new defaults (3 for HDDs and 10 for SSDs) and,
  if so, remove the option from their configuration entirely.

* monitors now have a `ceph osd info` command that will provide information
  on all osds, or provided osds, thus simplifying the process of having to
  parse `osd dump` for the same information.

* The structured output of ``ceph status`` or ``ceph -s`` is now more
  concise, particularly the `mgrmap` and `monmap` sections, and the
  structure of the `osdmap` section has been cleaned up.

* A health warning is now generated if the average osd heartbeat ping
  time exceeds a configurable threshold for any of the intervals
  computed.  The OSD computes 1 minute, 5 minute and 15 minute
  intervals with average, minimum and maximum values.  New configuration
  option ``mon_warn_on_slow_ping_ratio`` specifies a percentage of
  ``osd_heartbeat_grace`` to determine the threshold.  A value of zero
  disables the warning.  New configuration option
 ``mon_warn_on_slow_ping_time`` specified in milliseconds over-rides the
  computed value, causes a warning
  when OSD heartbeat pings take longer than the specified amount.
  New admin command ``ceph daemon mgr.# dump_osd_network [threshold]`` command will
  list all connections with a ping time longer than the specified threshold or
  value determined by the config options, for the average for any of the 3 intervals.
  New admin command ``ceph daemon osd.# dump_osd_network [threshold]`` will
  do the same but only including heartbeats initiated by the specified OSD.

* Inline data support for CephFS has been deprecated. When setting the flag,
  users will see a warning to that effect, and enabling it now requires the
  ``--yes-i-really-really-mean-it`` flag. If the MDS is started on a
  filesystem that has it enabled, a health warning is generated. Support for
  this feature will be removed in a future release.

* ``ceph {set,unset} full`` is not supported anymore. We have been using
  ``full`` and ``nearfull`` flags in OSD map for tracking the fullness status
  of a cluster back since the Hammer release, if the OSD map is marked ``full``
  all write operations will be blocked until this flag is removed. In the
  Infernalis release and Linux kernel 4.7 client, we introduced the per-pool
  full/nearfull flags to track the status for a finer-grained control, so the
  clients will hold the write operations if either the cluster-wide ``full``
  flag or the per-pool ``full`` flag is set. This was a compromise, as we
  needed to support the cluster with and without per-pool ``full`` flags
  support. But this practically defeated the purpose of introducing the
  per-pool flags. So, in the Mimic release, the new flags finally took the
  place of their cluster-wide counterparts, as the monitor started removing
  these two flags from OSD map. So the clients of Infernalis and up can benefit
  from this change, as they won't be blocked by the full pools which they are
  not writing to. In this release, ``ceph {set,unset} full`` is now considered
  as an invalid command. And the clients will continue honoring both the
  cluster-wide and per-pool flags to be backward comaptible with pre-infernalis
  clusters.

* The telemetry module now reports more information.

  First, there is a new 'device' channel, enabled by default, that
  will report anonymized hard disk and SSD health metrics to
  telemetry.ceph.com in order to build and improve device failure
  prediction algorithms.  If you are not comfortable sharing device
  metrics, you can disable that channel first before re-opting-in::

    ceph config set mgr mgr/telemetry/channel_device false

  Second, we now report more information about CephFS file systems,
  including:

    - how many MDS daemons (in total and per file system)
    - which features are (or have been) enabled
    - how many data pools
    - approximate file system age (year + month of creation)
    - how many files, bytes, and snapshots
    - how much metadata is being cached

  We have also added:

    - which Ceph release the monitors are running
    - whether msgr v1 or v2 addresses are used for the monitors
    - whether IPv4 or IPv6 addresses are used for the monitors
    - whether RADOS cache tiering is enabled (and which mode)
    - whether pools are replicated or erasure coded, and
      which erasure code profile plugin and parameters are in use
    - how many hosts are in the cluster, and how many hosts have each type of daemon
    - whether a separate OSD cluster network is being used
    - how many RBD pools and images are in the cluster, and how many pools have RBD mirroring enabled
    - how many RGW daemons, zones, and zonegroups are present; which RGW frontends are in use
    - aggregate stats about the CRUSH map, like which algorithms are used, how
      big buckets are, how many rules are defined, and what tunables are in
      use

  If you had telemetry enabled, you will need to re-opt-in with::

    ceph telemetry on

  You can view exactly what information will be reported first with::

    ceph telemetry show        # see everything
    ceph telemetry show basic  # basic cluster info (including all of the new info)

* Following invalid settings now are not tolerated anymore
  for the command `ceph osd erasure-code-profile set xxx`.
  * invalid `m` for "reed_sol_r6_op" erasure technique
  * invalid `m` and invalid `w` for "liber8tion" erasure technique

* New OSD daemon command dump_recovery_reservations which reveals the
  recovery locks held (in_progress) and waiting in priority queues.

* New OSD daemon command dump_scrub_reservations which reveals the
  scrub reservations that are held for local (primary) and remote (replica) PGs.

* Previously, ``ceph tell mgr ...`` could be used to call commands
  implemented by mgr modules.  This is no longer supported.  Since
  luminous, using ``tell`` has not been necessary: those same commands
  are also accessible without the ``tell mgr`` portion (e.g., ``ceph
  tell mgr influx foo`` is the same as ``ceph influx foo``.  ``ceph
  tell mgr ...`` will now call admin commands--the same set of
  commands accessible via ``ceph daemon ...`` when you are logged into
  the appropriate host.

* The ``ceph tell`` and ``ceph daemon`` commands have been unified,
  such that all such commands are accessible via either interface.
  Note that ceph-mgr tell commands are accessible via either ``ceph
  tell mgr ...`` or ``ceph tell mgr.<id> ...``, and it is only
  possible to send tell commands to the active daemon (the standbys do
  not accept incoming connections over the network).

* Ceph will now issue a health warning if a RADOS pool as a ``pg_num``
  value that is not a power of two.  This can be fixed by adjusting
  the pool to a nearby power of two::

    ceph osd pool set <pool-name> pg_num <new-pg-num>

  Alternatively, the warning can be silenced with::

    ceph config set global mon_warn_on_pool_pg_num_not_power_of_two false

* The format of MDSs in `ceph fs dump` has changed.

* The ``mds_cache_size`` config option is completely removed. Since luminous,
  the ``mds_cache_memory_limit`` config option has been preferred to configure
  the MDS's cache limits.

* The ``pg_autoscale_mode`` is now set to ``on`` by default for newly
  created pools, which means that Ceph will automatically manage the
  number of PGs.  To change this behavior, or to learn more about PG
  autoscaling, see :ref:`pg-autoscaler`.  Note that existing pools in
  upgraded clusters will still be set to ``warn`` by default.

* The pool parameter ``target_size_ratio``, used by the pg autoscaler,
  has changed meaning. It is now normalized across pools, rather than
  specifying an absolute ratio. For details, see :ref:`pg-autoscaler`.
  If you have set target size ratios on any pools, you may want to set
  these pools to autoscale ``warn`` mode to avoid data movement during
  the upgrade::

    ceph osd pool set <pool-name> pg_autoscale_mode warn

* The ``upmap_max_iterations`` config option of mgr/balancer has been
  renamed to ``upmap_max_optimizations`` to better match its behaviour.

* ``mClockClientQueue`` and ``mClockClassQueue`` OpQueue
  implementations have been removed in favor of of a single
  ``mClockScheduler`` implementation of a simpler OSD interface.
  Accordingly, the ``osd_op_queue_mclock*`` family of config options
  has been removed in favor of the ``osd_mclock_scheduler*`` family
  of options.

* The config subsystem now searches dot ('.') delineated prefixes for
  options.  That means for an entity like ``client.foo.bar``, it's
  overall configuration will be a combination of the global options,
  ``client``, ``client.foo``, and ``client.foo.bar``.  Previously,
  only global, ``client``, and ``client.foo.bar`` options would apply.
  This change may affect the configuration for clients that include a
  ``.`` in their name.

  Note that this only applies to configuration options in the
  monitor's database--config file parsing is not affected.

* RGW: bucket listing performance on sharded bucket indexes has been
  notably improved by heuristically -- and significantly, in many
  cases -- reducing the number of entries requested from each bucket
  index shard.

* MDS default cache memory limit is now 4GB.

* The behaviour of the ``-o`` argument to the rados tool has been reverted to
  its orignal behaviour of indicating an output file. This reverts it to a more
  consisten behaviour when compared to other tools. Specifying obect size is now
  accomplished by using an upper case O ``-O``.

* In certain rare cases, OSDs would self-classify themselves as type
  'nvme' instead of 'hdd' or 'ssd'.  This appears to be limited to
  cases where BlueStore was deployed with older versions of ceph-disk,
  or manually without ceph-volume and LVM.  Going forward, the OSD
  will limit itself to only 'hdd' and 'ssd' (or whatever device class the user
  manually specifies).

* RGW: a mismatch between the bucket notification documentation and the actual
  message format was fixed. This means that any endpoints receiving bucket 
  notification, will now receive the same notifications inside an JSON array
  named 'Records'. Note that this does not affect pulling bucket notification
  from a subscription in a 'pubsub' zone, as these are already wrapped inside
  that array.

* The configuration value ``osd_calc_pg_upmaps_max_stddev`` used for upmap
  balancing has been removed. Instead use the mgr balancer config
  ``upmap_max_deviation`` which now is an integer number of PGs of deviation
  from the target PGs per OSD.  This can be set with a command like
  ``ceph config set mgr mgr/balancer/upmap_max_deviation 2``.  The default
  ``upmap_max_deviation`` is 1.  There are situations where crush rules
  would not allow a pool to ever have completely balanced PGs.  For example, if
  crush requires 1 replica on each of 3 racks, but there are fewer OSDs in 1 of
  the racks.  In those cases, the configuration value can be increased.

* MDS daemons can now be assigned to manage a particular file system via the
  new ``mds_join_fs`` option. The monitors will try to use only MDS for a file
  system with mds_join_fs equal to the file system name (strong affinity).
  Monitors may also deliberately failover an active MDS to a standby when the
  cluster is otherwise healthy if the standby has stronger affinity.

* RGW Multisite: A new fine grained bucket-granularity policy configuration
  system has been introduced and it supersedes the previous coarse zone sync
  configuration (specifically the ``sync_from`` and ``sync_from_all`` fields
  in the zonegroup configuration. New configuration should only be configured
  after all relevant zones in the zonegroup have been upgraded.

* RGW S3: Support has been added for BlockPublicAccess set of APIs at a bucket
  level, currently blocking/ignoring public acls & policies are supported.
  User/Account level APIs are planned to be added in the future

* RGW: The default number of bucket index shards for new buckets was raised
  from 1 to 11 to increase the amount of write throughput for small buckets
  and delay the onset of dynamic resharding. This change only affects new
  deployments/zones. To change this default value on existing deployments,
  use 'radosgw-admin zonegroup modify --bucket-index-max-shards=11'.
  If the zonegroup is part of a realm, the change must be committed with
  'radosgw-admin period update --commit' - otherwise the change will take
  effect after radosgws are restarted.

* Monitors now have config option ``mon_allow_pool_size_one``, which is disabled
  by default. However, if enabled, user now have to pass the
  ``--yes-i-really-mean-it`` flag to ``osd pool set size 1``, if they are really
  sure of configuring pool size 1.

* librbd now inherits the stripe unit and count from its parent image upon creation.
  This can be overridden by specifying different stripe settings during clone creation.